NESEDF2B console login: 2023/11/25-16:24:04, [FV-1001], 19266, CHASSIS, INFO, NESEDF2B, Flow Vision daemon initialized. SNMP Research EMANATE/Lite Agent Version 16.2.0.9 Copyright 1989-2006 SNMP Research, Inc. ki_state_set: redundant ACTIVATE for instance 1 2023/11/25-16:24:18, [ZONE-1022], 19267, FID 128, INFO, NESEDF2B, The effective configuration has changed to SNM_BCSI. 2023/11/25-16:24:18, [FV-1002], 19268, FID 128, INFO, NESEDF2B, Flow Vision Config Replay Completed Successfully. Nov 25 16:24:20 All service instances on Active 2023/11/25-16:24:23, [EM-1034], 19269, CHASSIS, ERROR, Brocade6505, PS 2 set to faulty, rc=2000e. POST1: started running Sat Nov 25 16:24:23 JST 2023 POST1: Test #1 - Running Turboramtest 2023/11/25-16:24:24, [LOG-1000], 19273, CHASSIS, INFO, Brocade6505, Previous message repeated 4 time(s). 2023/11/25-16:24:26, [HIL-1610], 19274, CHASSIS, WARNING, Brocade6505, Fan/PS unit 2 not supplying power, fan speeds may not be available. Please ensure that the unit has power and the switch is on. POST1: Script PASSED with exit status of 0 Sat Nov 25 16:24:37 JST 2023 took (0:0:14) POST2: started running Sat Nov 25 16:24:40 JST 2023 POST2: Test #1 - Running portloopbacktest POST2: Script PASSED with exit status of 0 Sat Nov 25 16:25:09 JST 2023 took (0:0:29) 2023/11/25-16:25:10, [BL-1000], 19275, CHASSIS, INFO, Brocade6505, Initializing ports... 2023/11/25-16:25:10, [BL-1001], 19276, CHASSIS, INFO, Brocade6505, Port initialization completed. 2023/11/25-16:25:28, [TS-1001], 19277, FID 128, WARNING, NESEDF2B, NTP Query failed: 256. 2023/11/25-16:25:34, [FW-1010], 19278, FID 128, WARNING, NESEDF2B, Env Power Supply 2, is below low boundary(High=0, Low=1). Current value is 0 (1 OK/0 FAULTY). 2023/11/25-16:25:58, [FW-1424], 19279, FID 128, WARNING, NESEDF2B, Switch status changed from HEALTHY to MARGINAL. 2023/11/25-16:25:59, [FW-1427], 19280, FID 128, WARNING, NESEDF2B, Switch status change contributing factor Power supply: 1 bad. 2023/11/25-16:25:59, [FW-1431], 19281, FID 128, WARNING, NESEDF2B, Switch status change contributing factor Fan: 1 bad. 2023/11/25-16:26:50, [TS-1001], 19282, FID 128, WARNING, NESEDF2B, NTP Query failed: 256.
Brocade 6505 ファイバチャネルスイッチ 現状品
1.メーカー、型番:
*Brocade 6505 ファイバチャネルスイッチ 現状品。
2.
*通電、コンソールまでの確認のみです。その他、
詳細なチェックは行なって おりませんので、
ノーサポート、ノークレーム、ノーリターンでお願いします。
*外装に擦り傷・塗装剥げ・シール痕などがございます。
*その他、写真を御覧ください。 ご了承の上、検討してください。
3.付属品:本体のみです。その他、なし。
4.コンソール結果下記です。
The system is coming up, please wait...
U-Boot 1.1.3 (Nov 4 2015 - 11:09:27)
CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Tomtoo
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 52
wr_dqs_shift = 95
dll_dqs_delay_X = 28
dll_dqs_delay_X window = 3 - 54
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1c006000
DDR0_18=0x1c1c1c1c
DDR0_19=0x1c1c1c1c
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Tomtoo CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x03...
CPLD: Reseting Bridge & ASIC...
Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:
Checking system RAM - press any key to stop test
Checking memory address: 00100000
System RAM test using Default POST RAM Test succeeded.
set_bootstatus: BS_LOAD_OS, platform_idx = 16
Type run flash_nfs to mount root filesystem over NFS
Hit ESC to stop autoboot: 0
Map file at LBA sector 0x1a7758
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211398 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 2(threshold 5) abnormal reboots within 3000 seconds window(threshold)
sys_chip_init: class 0 max 24 Done
ethsw_ha_enabled = 1
uptime: 4293889121; sup_qid: 0
.
2023/11/25-16:23:53, [HAM-1004], 19265, CHASSIS, INFO, Brocade6505, Processor rebooted - Reset.
Fabric OS (NESEDF2B)
NESEDF2B console login: 2023/11/25-16:24:04, [FV-1001], 19266, CHASSIS, INFO, NESEDF2B, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2023/11/25-16:24:18, [ZONE-1022], 19267, FID 128, INFO, NESEDF2B, The effective configuration has changed to SNM_BCSI.
2023/11/25-16:24:18, [FV-1002], 19268, FID 128, INFO, NESEDF2B, Flow Vision Config Replay Completed Successfully.
Nov 25 16:24:20 All service instances on Active
2023/11/25-16:24:23, [EM-1034], 19269, CHASSIS, ERROR, Brocade6505, PS 2 set to faulty, rc=2000e.
POST1: started running Sat Nov 25 16:24:23 JST 2023
POST1: Test #1 - Running Turboramtest
2023/11/25-16:24:24, [LOG-1000], 19273, CHASSIS, INFO, Brocade6505, Previous message repeated 4 time(s).
2023/11/25-16:24:26, [HIL-1610], 19274, CHASSIS, WARNING, Brocade6505, Fan/PS unit 2 not supplying power, fan speeds may not be available. Please ensure that the unit has power and the switch is on.
POST1: Script PASSED with exit status of 0 Sat Nov 25 16:24:37 JST 2023 took (0:0:14)
POST2: started running Sat Nov 25 16:24:40 JST 2023
POST2: Test #1 - Running portloopbacktest
POST2: Script PASSED with exit status of 0 Sat Nov 25 16:25:09 JST 2023 took (0:0:29)
2023/11/25-16:25:10, [BL-1000], 19275, CHASSIS, INFO, Brocade6505, Initializing ports...
2023/11/25-16:25:10, [BL-1001], 19276, CHASSIS, INFO, Brocade6505, Port initialization completed.
2023/11/25-16:25:28, [TS-1001], 19277, FID 128, WARNING, NESEDF2B, NTP Query failed: 256.
2023/11/25-16:25:34, [FW-1010], 19278, FID 128, WARNING, NESEDF2B, Env Power Supply 2, is below low boundary(High=0, Low=1). Current value is 0 (1 OK/0 FAULTY).
2023/11/25-16:25:58, [FW-1424], 19279, FID 128, WARNING, NESEDF2B, Switch status changed from HEALTHY to MARGINAL.
2023/11/25-16:25:59, [FW-1427], 19280, FID 128, WARNING, NESEDF2B, Switch status change contributing factor Power supply: 1 bad.
2023/11/25-16:25:59, [FW-1431], 19281, FID 128, WARNING, NESEDF2B, Switch status change contributing factor Fan: 1 bad.
2023/11/25-16:26:50, [TS-1001], 19282, FID 128, WARNING, NESEDF2B, NTP Query failed: 256.
Fabric OS (NESEDF2B)
NESEDF2B console login:
ジャンク扱いで返品返金を対応しておりません。
*中古品となりますので外観は多少傷、汚れ、
使用感等ございますことご了承ください。
*送料は梱包材費など含みます。ご了承ください。
*写真で判断しご了承の上ご入札ください。
(テスト用品が付属されていません。ご注意してください)。
*キャンセルされる場合は落札金額の30%を頂戴いたします。
*入札の取り消しについて平日(月~金)09:00~17:00しか対応しておりません。
祝日,時間外に対応出来かねます。ご了承ください。
*追跡番号付いてない配送方法について
紛失、届かなかった場合は当方保証しておりません。
対応しておりません。ご了承ください。
*土曜・日曜・祝日は発送いたしません、
お急ぎの方はご遠慮ください。
*落札後7日経過しても連絡及び入金がない場合は
取り消しさせていただきます。
(その場合、自動的に「悪い」評価が付きます)。
*商品に関して質問がございましたら入札前質問提出してください。
落札後、ノークレーム、ノーリターンでお願いいたします。
ご理解の上、ご入札をお願い申し上げます。
*管理番号:A20720
この商品説明は オークション落札相場サイト「オークファン」出品テンプレート で作成されています。(ヤフオク専用)
Powered by aucfan.com