U-Boot 1.1.3 (Oct 23 2009 - 03:01:58)CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz) No Security/Kasumi support I2C boot EEPROM enabled Bootstrap Option G - Boot ROM Location I2C (Addr 0x54) Internal PCI arbiter enabled, PCI async ext clock used 32 kB I-Cache 32 kB D-CacheBoard: SpiritI2C: readyDRAM: Initializing DDRSDRAMDDR Init: speed = 132000002DQS calibration - Window detected:max_passing_cases = 52wr_dqs_shift = 95dll_dqs_delay_X = 30dll_dqs_delay_X window = 5 - 56DDR0_09=0x00011d5fDDR0_22=0x00267f0bDDR0_17=0x1e006000DDR0_18=0x1e1e1e1eDDR0_19=0x1e1e1e1eECC Enabling DONE512 MBPOST RAM test disabled.Now running in RAM - U-Boot at: 1fb32000trap_init : 0x0system inventory subsystem initializedFLASH: Spirit CFI Flash Driver Initialized4 MBATA interface setup: io_base=0xf8f00000, port=0x1f0, ctl=0x3f6PCI:Skip our host bridge 00 07 1657 0010 0280 18In: serialOut: serialErr: serialNet:Checking system RAM - press any key to stop testChecking memory address: 00100000System RAM test using Default POST RAM Test succeeded.set_bootstatus: BS_LOAD_OS, platform_idx = 3Type run flash_nfs to mount root filesystem over NFSHit ESC to stop autoboot: 0Map file at LBA sector 0x18d968## Booting image at 00400000 ... Image Name: Linux-2.6.14.2 Image Type: PowerPC Linux Multi-File Image (uncompressed) Data Size: 4267435 Bytes = 4.1 MB Load Address: 00000000 Entry Point: 00000000 Contents: Image 0: 3190917 Bytes = 3 MB Image 1: 1076503 Bytes = 1 MB## Current stack ends at 0x1FAF0BE0 => set upper limit to 0x00C00000## initrd at 0x0070B0D4 ... 0x00811DEA (len=1076503=0x106D17) Loading Ramdisk to 1f9e9000, end 1faefd17 ... OKinitrd_start = 1f9e9000, initrd_end = 1faefd17## Transferring control to Linux (at address 00000000) ...Installing Linux 2.6 KernelAttempting to find a root file system on hda2...INIT: version 2.78 bootingBypassing firmware validation.INIT: Entering runlevel: 3Starting Fabric OS Services...sys_chip_init: class 0 max 24 Doneethsw_ha_enabled = 1uptime: 4293889162; sup_qid: 0.2000/01/01-00:06:23, [HAM-1004], 97327, CHASSIS, INFO, IBM_2498_B40, Processor rebooted - RebootFabric OS (switch)switch console login: SNMP Research EMANATE/Lite Agent Version 16.2.0.9Copyright 1989-2006 SNMP Research, Inc.ki_state_set: redundant ACTIVATE for instance 12000/01/01-00:06:43, [FCR-1069], 97328, FID 128, INFO, switch, The FC Routing service is enabled.2000/01/01-00:06:43, [FCR-1068], 97329, FID 128, INFO, switch, The FC Routing service is disabled.All service instances on ActivePOST1: Started running Sat Jan 1 00:06:52 GMT 2000POST1: Test #1 - Running turboramtestPOST1: Script PASSED with exit status of 0 Sat Jan 1 00:06:54 GMT 2000 took (0:0:2)POST2: Started running Sat Jan 1 00:06:55 GMT 2000POST2: Test #1 - Running portloopbacktest (SERDES)POST2: Running diagshowPOST2: Script PASSED with exit status of 0 Sat Jan 1 00:07:03 GMT 2000 took (0:0:8)2000/01/01-00:07:04, [BL-1000], 97330, CHASSIS, INFO, IBM_2498_B40, Initializing ports...2000/01/01-00:07:04, [BL-1001], 97331, CHASSIS, INFO, IBM_2498_B40, Port initialization completed.Fabric OS (switch)switch console login: adminPassword:-----------------------------------------------------------------switch:admin> switchshowswitchName: switchswitchType: 66.1switchState: OnlineswitchMode: NativeswitchRole: PrincipalswitchDomain: 1switchId: fffc01switchWwn: 10:00:00:05:1e:89:**:**zoning: OFFswitchBeacon: OFFFC Router: OFFFC Router BB Fabric ID: 1Index Port Address Media Speed State Proto============================================== 0 0 010000 id N4 No_Light FC 1 1 010100 id N4 No_Light FC 2 2 010200 id N4 No_Light FC 3 3 010300 id N4 No_Light FC 4 4 010400 id N4 No_Light FC 5 5 010500 id N4 No_Light FC 6 6 010600 id N4 No_Light FC 7 7 010700 id N4 No_Light FC 8 8 010800 id N4 No_Light FC 9 9 010900 id N4 No_Light FC10 10 010a00 id N4 No_Light FC11 11 010b00 id N4 No_Light FC12 12 010c00 id N4 No_Light FC13 13 010d00 id N4 No_Light FC14 14 010e00 id N4 No_Light FC15 15 010f00 id N4 No_Light FC16 16 011000 id N4 No_Light FC17 17 011100 id N4 No_Light FC18 18 011200 id N4 No_Light FC19 19 011300 id N4 No_Light FC20 20 011400 id N4 No_Light FC21 21 011500 id N4 No_Light FC22 22 011600 id N4 No_Light FC23 23 011700 id N4 No_Light FC24 24 011800 -- N8 No_Module FC (No POD License) Disabled25 25 011900 -- N8 No_Module FC (No POD License) Disabled26 26 011a00 -- N8 No_Module FC (No POD License) Disabled27 27 011b00 -- N8 No_Module FC (No POD License) Disabled28 28 011c00 -- N8 No_Module FC (No POD License) Disabled29 29 011d00 -- N8 No_Module FC (No POD License) Disabled30 30 011e00 -- N8 No_Module FC (No POD License) Disabled31 31 011f00 -- N8 No_Module FC (No POD License) Disabled32 32 012000 -- N8 No_Module FC (No POD License) Disabled33 33 012100 -- N8 No_Module FC (No POD License) Disabled34 34 012200 -- N8 No_Module FC (No POD License) Disabled35 35 012300 -- N8 No_Module FC (No POD License) Disabled36 36 012400 -- N8 No_Module FC (No POD License) Disabled37 37 012500 -- N8 No_Module FC (No POD License) Disabled38 38 012600 -- N8 No_Module FC (No POD License) Disabled39 39 012700 -- N8 No_Module FC (No POD License) Disabledswitch:admin> licenseshowcQ9QeddbyedRARf2: Fabric licenseS9Ry9SzecyVASzA4: Fabric Watch licenseYEEDFaNJ4S7Hf3BRZ7EK7CtRJ3MZHACtB7aGR: Enhanced Group Management licenseGEETFrX3JTtrF3WJTTKXHCRWr9tfWTDWBSmRG: 8 Gig FC licenseswitch:admin> versionKernel: 2.6.14.2Fabric OS: v6.3.0bMade on: Thu Oct 29 19:46:42 2009Flash: Mon Jan 11 07:24:49 2010BootProm: 1.0.9switch:admin> sfpshowPort 0: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 1: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 2: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 3: id (sw) Vendor: BROCADE Serial No: WAA11014472**** Speed: 100,200,400_MB/sPort 4: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 5: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 6: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 7: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 8: id (sw) Vendor: BROCADE Serial No: WAA10851426**** Speed: 100,200,400_MB/sPort 9: id (sw) Vendor: BROCADE Serial No: WAA10851426**** Speed: 100,200,400_MB/sPort 10: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 11: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 12: id (sw) Vendor: BROCADE Serial No: WAA10851426**** Speed: 100,200,400_MB/sPort 13: id (sw) Vendor: BROCADE Serial No: WAA10851426**** Speed: 100,200,400_MB/sPort 14: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 15: id (sw) Vendor: BROCADE Serial No: WAA11014473**** Speed: 100,200,400_MB/sPort 16: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 17: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 18: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 19: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 20: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 21: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 22: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 23: id (sw) Vendor: BROCADE Serial No: WAA10905433**** Speed: 100,200,400_MB/sPort 24: --Port 25: --Port 26: --Port 27: --Port 28: --Port 29: --Port 30: --Port 31: --Port 32: --Port 33: --Port 34: --Port 35: --Port 36: --Port 37: --Port 38: --Port 39: --switch:admin> diagshowDiagnostics Status: Sat Jan 01 00:09:04 2000Slot: 0 UPORTSPort BPort Diag Active Speed FrTX FrRX LLI Errs Loopback0/0 15 OK DN 4G Auto -- -- --0/1 13 OK DN 4G Auto -- -- --0/2 11 OK DN 4G Auto -- -- --0/3 9 OK DN 4G Auto -- -- --0/4 14 OK DN 4G Auto -- -- --0/5 12 OK DN 4G Auto -- -- --0/6 10 OK DN 4G Auto -- -- --0/7 8 OK DN 4G Auto -- -- --0/8 7 OK DN 4G Auto -- -- --0/9 5 OK DN 4G Auto -- -- --0/10 3 OK DN 4G Auto -- -- --0/11 1 OK DN 4G Auto -- -- --0/12 6 OK DN 4G Auto -- -- --0/13 4 OK DN 4G Auto -- -- --0/14 2 OK DN 4G Auto -- -- --0/15 0 OK DN 4G Auto -- -- --0/16 39 OK DN 4G Auto -- -- --0/17 37 OK DN 4G Auto -- -- --0/18 35 OK DN 4G Auto -- -- --0/19 33 OK DN 4G Auto -- -- --0/20 38 OK DN 4G Auto -- -- --0/21 36 OK DN 4G Auto -- -- --0/22 34 OK DN 4G Auto -- -- --0/23 32 OK DN 4G Auto -- -- --0/24 31 OK DN 8G Auto -- -- --0/25 29 OK DN 8G Auto -- -- --0/26 27 OK DN 8G Auto -- -- --0/27 25 OK DN 8G Auto -- -- --0/28 30 OK DN 8G Auto -- -- --0/29 28 OK DN 8G Auto -- -- --0/30 26 OK DN 8G Auto -- -- --0/31 24 OK DN 8G Auto -- -- --0/32 23 OK DN 8G Auto -- -- --0/33 21 OK DN 8G Auto -- -- --0/34 19 OK DN 8G Auto -- -- --0/35 17 OK DN 8G Auto -- -- --0/36 22 OK DN 8G Auto -- -- --0/37 20 OK DN 8G Auto -- -- --0/38 18 OK DN 8G Auto -- -- --0/39 16 OK DN 8G Auto -- -- --Total Diag Frames Tx: 200Total Diag Frames Rx: 200switch:admin> chassisshowFAN Unit: 1Time Awake: 0 daysFAN Unit: 2Time Awake: 0 daysPOWER SUPPLY Unit: 1Time Awake: 0 daysPOWER SUPPLY Unit: 2Time Awake: 0 daysCHASSIS/WWN Unit: 1Header Version: 2Factory Part Num: 40-1000133-12Factory Serial Num: ALM0610****Manufacture: Day: 5 Month: 2 Year: 2009Update: Day: 29 Month: 11 Year: 2020Time Alive: 4170 daysTime Awake: 0 daysID: IBM0000CAPart Num: 0024980000B40Serial Num: 107****switch:admin> chassisnameIBM_2498_B40switch:admin>
●写真の通りの商品です。[No.2]未使用品★WatchGuard XTM 3 Series ファイアウォール XTM 330 Model:NC5AE7 UTMネットワークセキュリティ★。
●Login:admin/Password:password。▲Ω 新E 0119♪ 保証有 Panasonic【 Switch-M12eGLPWR+ (PN28128) 】パナソニック ESネットワークス PoE給電スイッチングハブ。
●それぞれ、SFP [4Gb]×24個付きです。《》【中古】Cisco WS-C2960XR-48TD-I Catalyst 2960-XRシリーズ Stackモジュール付き 電源二重 初期化。2台/48個の内、4個は着脱用Handle無し。Ω 新D 0123♪ 保証有 SubGate HanDreamnet【 SG2412GPoE 】ハンドリームネット スイッチハブ 20年製 領収書発行可・祝10000!取引突破!!。
●機器起動時は次の状態です。▽Juniper QFX3100-2RU QFabric Director Device HDDなし 中古。
●使用されていた商品ですが、全機能を検証する環境が無い為、それ以上の動作は未確認です。「D033」HP StorageWorks 8/8 San Switch スイッチングハブ 動作確認 有線LAN/HP AJ716A 8G 4点付き 現状出品。
●「電源が入らない」以外は、現状・ノークレーム扱いでの出品とさせて頂きます。M◆Cisco(シスコ)/スイッチ/Catalyst 2960-Xシリーズ/WS-C2960X-24TD-L V05/初期化済(1。
●出品は、写真の商品本体×2台のみ、です。M◆Cisco(シスコ)/スイッチ/Catalyst 2960-Xシリーズ/WS-C2960X-24TD-L V05/初期化済(4。電源ケーブル等、付属品は一切ありません。HP ProCurve◎2910al-24G(J9145A)◎24ポート ギガビットスイッチ◎初期化済み K0906。
●写真をご参照の上、ご入札のほど、宜しくお願いします。BUFFALO バッファロー 24ポートGigaハブ BS-GS2024 通電のみ確認 (管2OF)。
●発送は佐川急便ラージサイズ宅配便に限らせていただきます。◎ Cisco SF302-08P 8Port 10/100 PoE Managed Switch 初期化済。ご了承下さい。20☆A llied Telesis CentreCOM FS924TX V1☆10BASE-T/1000BASE-TX 24ポートHUB☆。
●送料は下記の「200サイズ」(2台1セットあたり)となります。Panasonic パナソニック Switch-M16PWR PN23169K PoE対応 16ポート L2スイッチングハブ 電源コード LANコード USB8GFM 動作確認済み 即決。
●こちらの商品は、沖縄および離島への発送はできません。▲Ω保証有 Σ★20932★JG924A HP 1920-24G Switch スイッチハブ 領収書発行可能 ・祝10000取引!! 同梱可。
●送料は佐川急便のホームページでご確認ください。【シスコ】スイッチ4点(WS-C2924-XL-EN 1点)(WS-C2960S-48TS-L V06 3点) 現状!! 管ざ9121。
●関東発 [飛脚宅配便・飛脚ラージサイズ宅配便]
●東京都江戸川区西一之江の倉庫にてのお渡しも可能です。M◆Cisco(シスコ)/スイッチ/Catalyst 2960-Xシリーズ/WS-C2960X-24TD-L V05/初期化済(7。
●その場合は無梱包・裸渡しとなります。▲Ω 新LB 0030k 保証有 NEC【 QX-S516FT-2G-PW 】100MベーシックPoE+ レイヤ2スイッチ 通電確認済 領収書発行可能。送料は発生しません。K5082461 CISCO WS-C2960CX-8TC-L V03 Switch AC付き 1点【通電ok、本体のみ】。
●営業時間は月曜日~金曜日、AM11:00~PM19:00となります。M◆Cisco(シスコ)/スイッチ/Catalyst 2960-Xシリーズ/WS-C2960X-24TD-L V05/初期化済(18。
●第1.3.5土曜日のみ、11:00~15:00に限り営業致します。M◆Cisco(シスコ)/スイッチ/Catalyst 2960-Xシリーズ/WS-C2960X-24TD-L V05/初期化済(6。
●第2.4土曜日・日曜日・祝日は休みになります。初期化済 HPE 5130 24G 4SFP+ 1slot HI Switch JH323A 24ポート L3 レイヤー3 イーサネット スイッチ ラック switch S010503。
●落札後のご連絡は取引ナビにてお願い致します。《》【中古】Cisco WS-C3650-24TD-E Catalyst 3650シリーズ 初期化。
●ヤフーからお客様に送られる自動落札メールの中に、当方の連絡先・取引方法が記載されております。#6009-1025 #2 ☆動作保証/領収書可☆ 初期化済み Cisco C3650-24TS-S V04 (WS-C3650-24TS-S V04) スイッチ 発送サイズ:140予定。
●ご一読の上、取引ナビにてご連絡をお願い致します。★中古 Cisco Catalyst 4500-Xシリーズ(WS-C4500X-16SFP+)ipbaseライセンス。
●こちらからのご連絡は、平日昼間のみとなります。《》【中古】NETGEAR XS724EM 10G/マルチギガビット24ポート アンマネージプラススイッチ。
●また、お取引後の評価ですが、不要のお客様が多い為にこちらからは入れておりません。Ω 新LE 0020k 保証有 SubGate HanDreamnet【 SG2420G-O 】ハンドリームネット セキュリティスイッチ 21年製・祝10000!取引突破!!。
●評価が必要なお客様は、併せて取引ナビにてのご連絡をお願い致します。▲Ω XY 15023# 保証有 YAMAHA【 SWX2210P-10G 】ヤマハ 10ポート1000BASE-T うち8ポートPoE+対応 スマートL2 PoE+スイッチ 領収書発行可能。